Ball valve in use or installation may occur internal leakage, frequent switch in use, or not in accordance with the requirements of the installation and other reasons, ball valve will not work normally, then, ball valve manufacturers that good, let's take a look!

Ball valve manufacturer
Reasons for leakage in the valve during construction:
Improper transportation and lifting methods cause overall damage to the valve and lead to leakage in the valve;
When leaving the factory, after applying water pressure, the valve is not dried and anti-corrosion treatment, resulting in rust on the sealing surface and internal leakage;
The protection of the construction site is insufficient, the blind plate is not installed at both ends of the valve, and foreign bodies such as rain and sand enter the valve seat, resulting in leakage;
During installation, the valve seat is not injected with grease, and foreign matter enters the rear of the valve seat, causing internal leakage during welding;
The valve was not installed in the fully open position, causing damage to the ball. During welding, if the valve is not fully open, the welding splash will damage the ball, and the ball with the welding splash will damage the valve seat when opening and closing, resulting in internal leakage;
Damage to sealing surface caused by construction residues such as welding slag
If the factory or installation position is incorrect, resulting in leakage, offset from the mounting Angle of the stem drive bushing and other accessories, the valve will leak.
Causes of leakage in the valve during operation:
The most common reason is that the operation manager does not maintain the valve in consideration of the relatively expensive maintenance costs, or does not perform preventive maintenance on the valve due to the lack of scientific valve management and maintenance methods, leading to the failure of the equipment in advance.
Internal leakage caused by incorrect operation or failure to follow maintenance procedures;
During normal operation, the construction residue scratches the sealing surface, causing internal leakage;
Internal leakage caused by damage of sealing surface caused by improper trachea;
If the valve is not maintained or not moved for a long time, the valve seat and ball will be stuck, and the sealing damage will be caused when the valve is opened and closed, thus forming internal leakage;
The valve switch is not sufficient, there will be internal leakage, no matter which ball valve switch position, usually tilt 2 to 3 May cause leakage.
Procedure for handling leakage in ball valve
First check the position limit of the valve to determine whether the internal leakage of the valve can be solved by adjusting the position limit.
First inject a certain amount of grease to confirm whether it can prevent leakage. At this time, the injection speed must be slowed down, while observing the change of the oil gun outlet pressure gauge pointer to determine the internal leakage of the valve.
If the leak cannot be stopped, the early injection of sealing grease may harden and the sealing surface may be damaged, resulting in internal leakage. At this time, it is recommended to inject valve cleaning solution to clean the sealing surface and seat of the valve. Generally, impregnation is at least 30 minutes, if necessary, impregnation for a few hours to a few days, and then the following treatment is carried out after all the cured material is dissolved. It is best to open and close the valve several times during this process.